Why hydronic balancing should be on every social housing provider’s radar
Gareth Ash, Marketing Manager at Danfoss, explains the three main types of hydronic balancing – static, dynamic, and auto-balancing – highlighting where each approach is best applied and how it can help create high-performing, energy-efficient heating systems.
As the UK accelerates towards its Net Zero targets, housing providers face increasing pressure to modernise infrastructure, improve energy efficiency, and address fuel poverty – all while ensuring tenant comfort and controlling operational costs. Hydronic balancing is among the most effective yet often overlooked measures in this effort.
Hydronic balancing ensures that water used for heating is evenly and efficiently distributed throughout a building. By fine-tuning the flow of heating water, it guarantees that each radiator or heating circuit receives exactly the right amount at the right time, avoiding overheating in some rooms and underheating in others.
More than 80% of the UK’s existing heating systems are poorly balanced, leaving vast potential for improvement. This is particularly significant for social housing apartment blocks, where older systems often struggle to maintain consistent temperatures across multiple units. Residents on the upper floors may complain of cold rooms, while others experience overheating. These imbalances increase energy consumption, higher costs, and tenant dissatisfaction.
Static balancing: tried, tested, and cost-effective
Static hydronic balancing uses pressure-dependent valves, like Danfoss’ RA-N combined with mechanical radiator thermostats set for full-load conditions to regulate and maintain the flow at the set value. It is a straightforward solution ideally suited to systems where the building load is relatively stable and predictable. Static balancing is most appropriate for apartment buildings, offices, schools, hospitals and hotels, particularly in retrofits where radiator valves without pre-setting functionality may already be installed.
While cost-effective, static systems do not adapt to fluctuating heating demands, making them inefficient during partial load conditions (spring and autumn). Nevertheless, where the heating load is well understood, static balancing offers a good balance of performance and cost, especially when commissioning is simplified using tools such as the Danfoss Installer App.
Dynamic balancing: precision under varying loads
Dynamic balancing addresses the limitations of static systems by maintaining consistent flow rates even when demand fluctuates. Using pressure-independent radiator valves or differential pressure controllers, dynamic balancing maintains the required flow at the radiator or circuit constant under all operating conditions. This ensures that each radiator or circuit receives the required amount of water to deliver the best performance, whether under full load or partial load.
Dynamic balancing is suited to all building types It helps maintain consistent return water temperatures, which is critical for ensuring condensing boilers operate efficiently (i.e. condense) for longer or for meeting specific return temperature requirements in systems like heat networks and district heating schemes. Ultimately, it delivers higher year-round energy savings and enhances user comfort by reducing issues such as flow noise, which can be common in systems relying on static methods. In these applications, Danfoss solutions such as RAS-B2 for residential applications or RA-DV, ASV-PV differential pressure controllers, and ASV-BD partner valves help maintain a stable, quiet, and energy-efficient system in larger applications with multiple branches (offices, schools, apartment buildings). For underfloor heating, Icon2 can maintain the right balance in every room thanks to the built in Automatic Balancing algorithms in its software.
Balancing for district heating networks
Virtus is Danfoss’ series of digitally empowered pressure and flow controllers for hydronic balancing and control in district heating and cooling networks. Optimal hydronic balance can result in up to 20% energy saving and improved comfort because of perfect temperature (delta T) control. Virtus is a range of heavy-duty differential pressure regulators and flow regulators for demanding district heating and cooling applications. They are designed to be used in power plants for energy production, transportation networks, distribution network stations and subscriber (building) substations.
Digital optimisation with iSET and iNET
All Virtus controllers are built up from a valve and a pressure actuator (also known as a pressure regulator) and are self-acting. This means they work independent of electrical energy, ensuring a high level of reliability. Most of the controllers can optionally be equipped with a remotely accessible digital actuator to optimise the performance. There is iNET functionality for intelligent NETwork balancing and iSET functionality for intelligent substation SETting. Via AMEi 6 digital actuators, the set pressure or flow on the Virtus pressure actuator is electronically adjusted to increase stability and precision, especially in partial load system conditions.
Real-world success: two case studies
In two large-scale district energy projects, Gallions Point and Newbury Racecourse, developers Telford Homes and David Wilson Homes partnered with E.ON to ensure energy-efficient and comfortable heating. The Danfoss Virtus controller, combined with iSET technology, was selected to handle the demands of these extensive systems. These solutions provided demand-responsive flow and pressure control, optimising performance and ensuring reliability across each network. Read full story here.
In Sweden, a 12-apartment block managed by the cooperative HSB was connected to district heating. By integrating Leanheat Building, a cloud-based AI platform, into the site’s substation, HSB was able to cut energy use by 10.9% within just five months. The AI platform detected inefficiencies, enabling targeted upgrades that included replacing static valves with Danfoss ASV-PV and ASV-BD valves and installing RA-N radiator valves and mecahnical radiator thermostats. These changes not only balanced the system dynamically but also delivered a further 10.2% reduction in energy use, alongside improved resident comfort and system noise reduction. Read more here.
Supporting long-term strategy
For local authorities and housing associations, hydronic balancing aligns seamlessly with broader strategic objectives. It contributes to meeting Energy Performance Certificate (EPC) and Net Zero requirements, while also helping to reduce ongoing operational and maintenance costs. Importantly, it enhances resident comfort and supports better health outcomes by providing more stable indoor temperatures. Moreover, it offers a clear demonstration of the sustainable use of public funding and grant allocations.
In an environment where retrofit budgets face increasing scrutiny, it is essential to prioritise solutions that deliver measurable results efficiently. Hydronic balancing stands out as a low-profile yet high-impact intervention, offering meaningful improvements with minimal disruption.
To learn more about best practices or explore Danfoss solutions for hydronic balancing, visit danfoss.com
Danfoss is exhibiting at elementalLONDON, the UK’s leading event for advancing the efficiency of buildings, for the specification community, on 19-20 November at Excel, London. To register for your free ticket, click here.