Achieving optimal heating performance depends on more than just the heat pump unit itself, says Shane Cox of Itherme.
The heat pump market is booming. The Heat Pump Association recorded a 63% increase in domestic heat pump installations last year – a volume that is only set to increase. The upcoming Warm Homes Plan, alongside the expansion of the BUS Scheme and changes to Permitted Development Rights, mean that more funding than ever is available to support heat pump adoption in an even broader range of buildings.
However, heat pump performance depends on more than just the technology itself. It relies on an efficient, well-designed, system. Because regardless of how efficient a heat pump may be, undersized or poorly configured emitters can undermine design intent, impacting comfort, efficiency, acoustics and overall performance.
Heat pumps are brilliant, but they are not the silver bullet – they require a holistic approach to perform optimally. Yet, too many installations still treat legacy boiler circuits as though they are compatible with low-temperature heat pumps.
Given that traditional radiator systems are designed for up to 70-80°C operation, they will often lose more than half their heat output once flow temperatures drop into the mid-40s. Raising the flow temperature of a heat pump system simply masks the problem – driving inefficiencies, increasing running costs and causing excessive heat pump cycling.
Rethinking heat distribution
Ultimately, the comfort a heat pump delivers is determined by how effectively heat is transferred into the living space. Underfloor heating (UFH) can provide stable, even warmth at lower flow temperatures when it is designed using accurate thermal load calculations for the building. Its broad surface area and consistent heat output complement the way heat pumps operate, which is why many call them the perfect match, particularly when specified from the beginning of a project.
Retrofit applications, however, introduce additional complexity. The UK housing stock presents specifiers with a wide mix of property types, each with its own performance challenges and simply retaining existing radiators or replacing on a like-for-like basis is rarely sufficient.
Instead, system specification should begin with detailed building diagnostics. This involves calculating room-by-room heat losses; reviewing insulation performance and cold bridges; modelling suitable flow temperatures; and confirming whether existing emitters are capable of meeting peak demand under low-temperature conditions.
This diagnostic stage often reveals that original radiators are undersized for heat pump conditions. If those insights are ignored, the outcome is predictable: slow warm-up times, persistent cold spots, and heat pumps forced to cycle excessively to overcompensate.
By contrast, when the emitters are sized to meet the bespoke needs of a property using thermal analysis, performance can change significantly. Homes that previously struggled to reach comfortable temperatures can achieve a more even balance, with consistent room-to-room warmth and systems running in a stable, efficient rhythm rather than repeatedly starting and stopping.
This approach is at the core of Itherme’s UFH offering, with engineered screeded, joisted and low-build up retrofit systems, manufactured using high-quality components exclusively from the UK and Europe.
Choosing the right emitters for each application is essential, as the comfort a heat pump provides is shaped less by the maximum water temperature and more by how evenly and reliably heat is supplied throughout the home.
When emitters are correctly specified and manufactured using reliable components, consistent performance follows naturally. When they are not, uneven comfort levels from room to room are almost inevitable – and the heat pump itself is often blamed for issues routed in system design, nor the technology.
Engineering for silence
But poor system design affects more than just thermal comfort. Noise complaints are often one of the first signs that a heating system is not operating as intended. When emitters aren’t dissipating heat effectively, the heat pump is forced to work harder: increasing flow rates, ramping up pump activity, and cycling more frequently. This can translate into higher fan activity and noticeable operational noise, even though there is no mechanical fault with the equipment itself.
We recently assessed a heritage property where the heat pump installation was technically sound, but had become unpopular due to issues around noise. After recalculating the emitter surface areas and optimising system flow, we were able to reduce the sound levels considerably, while overall energy performance improved at the same time. Cases like this demonstrate that a “noisy heat pump” is rarely a product fault – more often, it reflects a symptom of a system that has not been properly engineered for low-temperature operation.
Acoustic performance is a key consideration in Itherme’s system design – our Gypsumdek 18 retrofit system, for example, can be installed directly on top of a vast range of acoustic products without the need for mechanical fixings. This preserves the effectiveness of the acoustic material beneath the system, supporting quieter operation, a factor which is particularly important in multi-storey buildings.
Performance begins at design
The principle behind getting the emitter decisions right mirrors the challenges we see in construction more broadly: when material decisions are made too late or the wrong products are specified, waste, inefficiency, rework and underperformance become commonplace.
Heat pumps systems are no exception. If emitters are not designed for low-temperature operation from the outset, the entire system inevitably becomes compromised. And, once those design limitations are built into a project, correcting them later can be complex and costly.
Considering emitters early in the design process is essential if heat pumps are to perform effectively at scale. Without doing so, the gap between design intent and real-world outcomes grows, weakening confidence in the technology and risking the industry’s progress.
But when we get the foundations right, large-scale heat pump adoption can be driven based on proven performance, not policy alone.