Credit: Crovik Media/Shutterstock
Julian Boss, Principal Consultant at Turner & Townsend, working on the Retrofit Information, Support and Expertise (RISE) programme, explains everything you need to know about recent changes to RdSAP.
Energy Performance Certificates (EPCs) are a widely known feature of building management, often used as a shorthand for a building’s energy efficiency.
A lesser known, but just as critical part of the picture is the Reduced Data Standard Assessment Procedure – or RdSAP. This is the method through which a building’s energy efficiency is calculated, and it forms the basis for producing all EPC ratings.
An accurate RdSAP assessment leads to an accurate EPC, which in turn supports housing providers to make the best decisions about refurbishment, retrofitting, and energy upgrades. And as government funded retrofit schemes like Warm Homes are tied to EPC ratings, a full understanding of RdSAP helps housing providers prioritise work and unlock funding.
On 15 June 2025, an updated version of RdSAP was published, with a range of changes and improvements made. The changes are significant, focused on accuracy, relevancy and detail – and having a full understanding of the new process is essential for anyone planning or developing a domestic retrofit project.
What are the aims of the changes to RDSAP?
More accurate assessments: this new version of the assessement, RdSAP 10 (which replaces the previous RdSAP 2012) will require more actual on-site measurements rather than relying on assumptions, as well as having better categorisation and efficiency measurements for different types of heating systems. This will give homeowners and landlords a better idea on the effectiveness of insulation, heating systems and energy performance assessments.
Integration of renewable technologies: The new version will offer a more comprehensive assessment of renewable energy technologies.
New age band and regions: The introduction of a new age band (properties built from 2023 onwards) and new regions will make the assessments more relevant and granular.
What changes are being made?
Key changes from the previous version include:
- Measurements for all windows now required
- Thermal properties of insulation revised
- Roof insulation details have more options
- Air pressure test result can be used
- More accurate calculation for hot water consumption and lighting energy
- Additional technologies: window shutters have been added as a new feature, and hot water tank size and insulation thickness are now included
- PV Diverter for water heating and PV batteries have now been added.
Further revisions include updates across several areas. For example, RdSAP10-specific fuel prices now reflect emission factors and primary energy factors. Heating and ventilation changes include revised distribution loss factors for communal heating networks and updated chimney and flues air flow rates. Building characteristics now incorporate updated reference building characteristics, the infiltration rate calculation now includes low pressure pulse testing results and there has been the removal of summer gains check.
I’m about to start delivering a Warm Homes funded project, does this impact me?
With the Warm Homes schemes, RdSAP 10 will be a key component for various elements of policy. For example, when calculating performance metrics such as EPCs, RdSAP 10 will be used. Also, measures affecting energy performance or heating that are allowed under the the Warm Homes: Social Housing Fund and Warm Homes: Local Grant schemes must be compatible with the RdSAP 10 at the time of delivery.
In particular, PV batteries – a type of battery storage installed to work alongside solar PV panels – have now become an eligible measure under the Warm Homes: Social Housing Fund and Warm Homes: Local Grant schemes, because PV batteries have also been integrated into RdSAP 10 (it should be noted that PV batteries can only be installed under the Warm Homes schemes where it complements an existing or new Solar PV system).
How changes to RdSAP affects retrofit businesses
The changes to RdSAP also impact throughout the supply chain for manufacturers, distributors, installers and end users, as well as compliance enforcers and regulators, across a range of areas. For example, the new procedure now requires more accurate assessments throughout; for example windows will require exact measurements for each opening, including details about frame type and solar transmittance, rather than relying on assumptions as per previous versions. The increased focus on heat pumps within the new RdSAP (favouring their use where properties are already well insulated) will most likely see demand for this type of technology increase, affecting supply and cost. And, as RdSAP 10 now includes a more detailed assessment criteria to provide a clearer picture of a home’s energy related features, pressure increases on suppliers to rise to this standard.
What next?
RISE (the free support service funded by the Department for Energy Security and Net Zero to support social housing providers, local authorities and their supply chains plan and deliver successful domestic retrofit programmes) has produced a range of materials to walk housing providers and retrofit businesses through these changes to RdSAP. Through Masterclasses, advice packs and direct support, RISE breaks down the changes to the procedure, explains why these matter to providers and how they can respond to the changes.
RISE is here to help housing providers and their supply chains get up to speed with RdSAP10, with a range of resources to help:
Download the full RDSAP10 Advice Pack for suppliers here (RISE website).
Follow the RISE YouTube channel, to watch recent Masterclasses on RdSAP delivered by the RISE team (RISE YouTube channel)
To learn RdSAP, visit elementalLONDON, the UK’s leading event for advancing the efficiency of buildings, for the specification community, on 19-20 November at Excel, London. To register for your free ticket, click here.